Ion Science High Dynamic Range Photoionization Detector for Volatile Organic Compounds

The Ion Science PhoCheck Tiger VOC detector offers the widest measurement range and fastest response time of any handheld VOC detector on the market, with a dynamic detection range of 1 ppb to 20,000 ppm, and a response rate of just two seconds. It uses Ion Science’s advanced patented Fence Electrode technology, a three-electrode format that increases resistance to humidity and contamination.

PhoCheck Tiger's rugged design and protective, removable rubber boot withstand the harshest environments — and it's rated intrinsically safe by ATEX, IECEx, and cUL. The large, clear backlit display allows for easy viewing in any light condition. An integrated light helps you direct the instrument’s probe into dimly lit areas.

Looking for a detector for benzene or total aromatic compounds? See the Ion Science Tiger Select.

Key Specifications

  • Dynamic range ppb to 20,000 ppm for specific volatiles
  • Pre-programmed time-weight average (TWA) and short-term exposure limits (STEL) for up to 450 gases
  • Accuracy to ±5% display reading ± one digit
  • Intrinsically Safe ATEX, IECEx and CUL approvals
  • Easy change miniPID detector, electrode stack and lights
  • LED, vibratory, and audible alarms
  • Logs >120,000 data points including date and time stamp, 33 hours at one log per minute
  • Battery life up to 30 hours — Certified to be changed within hazardous areas

Supporting Documentation

Click the file icon to view the file online, or right-click on the file icon and select "Save Target As..." to download the file to disk for later viewing.

Mobibrix QR Code: ZNBTBQ