Loading...

6200D LoFlo Balometer by TSI Alnor - Capture Hoods for Low Air Volumes

6200D
As low as $115.00
When the air volume you're measuring is too low for a TSI AccuBalance 8375 to read accurately, try the TSI Alnor LoFlo air capture hoods. The TSI Alnor 6200 measures supply and return air flows from 10 to 500 CFM, so it's great for residential testing and small building spaces. Even with the 2-foot-square hood attached, the light-weight (6.5 lb) 6200 is compact, at a total hight of only 35", so it'll fit in tight spaces easily. The simulated analog display shows air trends and digital readings.

The TSI Alnor LoFlo 6200D Balometer® is a lightweight, compact airflow capture hood designed specifically for very low flow applications. It accurately measures supply or return air volume from 10 to 500 CFM (17–850 m³/h, 4.7–236 l/s), making it the ideal choice for verifying low-flow diffusers, testing critical environments like cleanrooms and labs, and balancing low-volume HVAC systems.

Its unique venting system minimizes resistance effects, while one-point, two-point, and vent open/closed measurement modes provide flexibility and accuracy across the full range. Customers choose the LoFlo Balometer® because it provides high accuracy (±3% + 5 CFM) in the low-volume range where traditional capture hoods struggle, ensuring confidence in airflow measurements that are critical to safety and compliance.

Rental Includes: 6200 LoFlo Balometer (battery pack removed during transit), 2 × 2 ft hood, hood kit frame (4 pieces), hood kit poles (4), user manual, carrying case, and calibration certificate

  • Key Specs

    • Flow Range: 10–500 CFM (17–850 m³/h, 4.7–236 l/s)

    • Accuracy: ±3% of reading + 5 CFM (±3% + 8.5 m³/h, 2.4 l/s)

    • Resolution: 1 CFM, 1 l/s, 0.1 l/s (depending on range)

    • Display: 3.5-digit LCD with simulated analog scale

    • Weight: ~6 lbs (2.7 kg) with hood, 4.6 lbs (2.1 kg) base only

    • Hood Sizes: 16 × 16 in. or 2 × 2 ft.

    Battery Life & Data Storage

    • Powered by 4 C-size alkaline batteries (NiCd optional)

    • Battery Life: Minimum 10 hours of continuous use

    • No onboard datalogging (real-time display only)

More Information
SKU 6200D
Manufacturer TSI Alnor
Kit Contents

6200 LoFlo Balometer (battery pack removed during transit), 2 × 2 ft hood, hood kit frame (4 pieces), hood kit poles (4), user manual, carrying case, and calibration certificate

Shipping Dimensions (LxWxD) 24x16x16
Weight (lbs) 14.000000
Power Replaceable C Alkaline Batteries

Write Your Own Review
You're reviewing:6200D LoFlo Balometer by TSI Alnor - Capture Hoods for Low Air Volumes
Your Rating